Rev. bras. ortop ; 56(2): 268-270, Apr.-June 2021. tab, graf
Article in English | LILACS | ID: biblio-1251343

ABSTRACT

Abstract Septic arthritis of the pubic symphysis is a rare condition. Risk factors include trauma, low-grade infection, urological or gynecological procedures, malignant tumors of the pelvis, sports, and intravenous drug abuse. This report describes a case of septic arthritis of the pubic symphysis in a 23-year-old male patient with no history of pelvic surgery, previous infections, or intense physical activity. Arthritis was diagnosed by blood culture positive for Enterococcus spp. and yeasts, and the patient was treated with antibiotics. This case emphasizes the importance of complementary exams to aid the treatment of septic arthritis of the pubic symphysis and shows that an invasive procedure, such as pubic symphysis puncture biopsy, may not be required.


Resumo A artrite séptica da sínfise púbica é uma condição rara. Os fatores de risco são trauma, infecção de baixo grau, procedimentos urológicos ou ginecológicos, tumores malignos da pelve, prática de esportes e uso de drogas intravenosas. O presente relato descreve um caso de artrite séptica da sínfise púbica em um paciente do sexo masculino, de 23 anos, sem história de cirurgias pélvicas, infecções prévias ou atividade física intensa. A artrite foi diagnosticada pela hemocultura que revelou crescimento de Enterococcus sp + leveduras, e o paciente foi tratado com antibioticoterapia. Este caso enfatiza a importância de exames complementares no auxílio do tratamento da artrite séptica da sínfise púbica, e demonstra que procedimentos invasivos, tais como a punção da sínfise púbica, podem não ser necessários.


Subject(s)
Humans , Male , Adult , Osteitis , Pubic Symphysis , Arthritis, Infectious , Enterococcus , Anti-Bacterial Agents
2.
Rev. bras. ortop ; 54(2): 156-164, Mar.-Apr. 2019. tab, graf
Article in English | LILACS | ID: biblio-1013699

ABSTRACT

Abstract Objective To compare pre- and postoperative variation of radiographicmeasurements of the Böhler angle (BA) in fractures with two types of deviations: severe and moderate. Methods Pre- and postoperative BAs in 31 calcaneal fracture radiographs were retrospectively analyzed. A total of 4 patients were female (6.5%) and 26 were male (83.9%), with age ranging from 23 to 72 years old, and a mean age of 44.5 years old. Results The results show that the postoperative BA was significantly larger than the preoperative BA (p = 0.000). At the intraevaluator and overall assessments, the postoperative BA was, on average, 10.6° higher than the preoperative measure. The postoperative angle was, on average, 108% higher than the preoperative angle. In the global assessment, the agreement between evaluatorswas excellent, bothregarding the estimated point value (0.98) and the intraclass correlation (ICC) confidence interval (CI). Conclusion In the global analysis, the postoperative BAs were, on average, significantly higher than the preoperativemeasurements. The farther from the normal range (20° to 40°) the preoperative angle is, the greater the difference after the surgery. When the preoperative angle was normal, the postoperative angle was, on average, 1.28 times the preoperative measurement. If the preoperative BA was abnormal, the postoperative angle was, on average, 17.3 times the preoperativemeasurement. It was demonstrated that more severe fractures present better anatomic results when compared with moderate fractures. The present study also confirms a good interobserver correlation for the BA.


Resumo Objetivo Comparar a variação dos resultados dasmedidas radiográficas do ângulo de Böhler, no pré e pós-operatório, em fraturas com dois tipos de desvio: graves e moderadas. Métodos: O ângulo de Böhler foi analisado retrospectivamente em 31 radiografias pré e pós-operatórias de fraturas do calcâneo. Quatro pacientes eram do sexo feminino (6,5%) e 26 do masculino (83,9%), entre 23 e 72 anos, média de 44,5. Resultados As medidas pré e pós-operatória demonstraram que o ângulo de Böhler após a cirurgia foi significativamente maior do que o ângulo de Böhler pré-operatório (p-valor = 0,000). Nas análises intraobservador e global, o ângulo de Böhler pósoperatório foi, em média, 10,6 graus maior do que no pré-operatório. O ângulo pósoperatório foi, em média, 108% maior do que o ângulo pré-operatório. No global, a concordância entre os avaliadores é excelente, tanto em relação ao valor pontual estimado (0,98) quanto em relação ao intervalo de confiança do ICC. Conclusão Na análise global, verificou-se que asmedidas do ângulo de Böhler no pósoperatório são, em média, significativamente maiores do que as do ângulo préoperatório. Quanto mais distante da faixa de normalidade (20 a 40 graus) estiver o ângulo pré-operatório, maior a diferença no ângulo após a cirurgia. Quando o ângulo pré-operatório está na faixa de normalidade, o ângulo pós-operatório será, em média, 1,28 vez o ângulo pré-operatório; se o ângulo de Böhler pré-operatório estiver fora da


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Calcaneus , Radiography , Fractures, Bone , Intra-Articular Fractures
3.
Rev. bras. ortop ; 53(1): 88-93, Jan.-Feb. 2018. graf
Article in English | LILACS | ID: biblio-899246

ABSTRACT

ABSTRACT Objective: To determine the ideal working area for a simple transverse fracture line treated with a bridge plate. Methods: A 2-D finite element analysis of a hypothetical femur was performed for the quantitative evaluation of a large-fragment titanium alloy locking plate based on the precept of relative stability in a case of a simple transverse diaphyseal fracture. Two simulations (one case of strain and another case of stress distribution) were analyzed in three unique situations according to the von Mises stress theory. Load distributions were observed when the bone was subjected to a single vertical load of 1000 N. Results: The longer the length of the implant flexion, which coincided with the working area of the plate, the greater the flexion of the implant. The highest concentrations of stress on the plate occurred in the region around the screws closest to the bone gap. The closer the screws to the fracture site, the greater the demands on the plate. Conclusion: When using a large-fragment titanium alloy locking plate to stabilize a simple transverse fracture based on the precept of relative stability (bridge plate), there must be considerable distance between the proximal and distal screws closest to the fracture line. The farther away this fixation is, the lower the stress on the plate and the greater the dissipation of force in the form of deflection.


RESUMO Objetivo: Determinar qual é a área de trabalho ideal em uma fratura de traço simples transverso tratada com placa em ponte. Métodos: Foi feita uma análise bidimensional de elementos finitos em um fêmur hipotético para avaliação quantitativa de uma placa bloqueada para grandes fragmentos feita de liga de titânio, usada com o princípio de estabilidade relativa em uma fratura diafisária de traço simples e transverso. Foram analisadas duas simulações, uma de deformação e outra de distribuição de tensão, de acordo com a teoria de von Mises, em três situações distintas. Foram observadas as distribuições de carga quando o osso foi submetido a uma carga monotônica vertical de 1.000 N. Resultados: Quanto maior o comprimento de flexão do implante, o que coincidiu com a área de trabalho da placa, maior a flexão dele. A maior concentração de tensão na placa foi observada na região dos parafusos mais próximos do defeito ósseo. Quanto mais próximos os parafusos do foco de fratura, maior a demanda sobre a placa. Conclusão: Ao usar uma placa bloqueada para grandes fragmentos feita de liga de titânio para estabilizar uma fratura de traço simples e transverso pelo princípio de estabilidade relativa (placa em ponte), a distância entre os parafusos mais próximos do traço de fratura proximal e distalmente deve ser longa. Quanto mais distante essa fixação, menor a concentração de tensão na placa e maior a dissipação de esforços na forma de deflexão.


Subject(s)
Bone Plates , Bone Regeneration , Finite Element Analysis , Fracture Fixation, Internal
4.
Einstein (Säo Paulo) ; 16(1): eRC4037, 2018. graf
Article in English | LILACS | ID: biblio-891461

ABSTRACT

ABSTRACT Periprosthetic fractures is a severe complication after joint replacement. The rapidly increase of reverse shoulder arthroplasty surgeries, periprosthetic humeral fractures, which are described as rare, may increase in the near future. We report the case of displaced humeral fracture bellow the stem of reverse shoulder prosthesis. The patient was an 85-year-old woman who had a total shoulder replacement 6 years previously. The surgical solution consisted of plate osteossynthesis and cerclage. This report describes an unprecedented case in Brazilian literature; and gives an overview of the existing literature including this injury classification.


RESUMO As fraturas periprotéticas do ombro representam uma grave complicação após a substituição da articulação. Devido ao rápido aumento do número de cirurgias de artroplastia reversa no ombro, as fraturas periprótese do úmero, descritas como raras, podem aumentar no futuro próximo. Descrevemos um caso de fratura desviada do úmero abaixo do componente umeral de uma artroplastia reversa. A paciente era uma mulher de 85 anos de idade, que tinha uma artroplastia reversa do ombro há 6 anos. O tratamento cirúrgico consistiu em osteossíntese com placa, parafusos e cerclagem. Os objetivos do presente trabalho foram reportar um caso inédito na literatura brasileira, e revisar a literatura existente e as classificações da lesão.


Subject(s)
Humans , Female , Aged, 80 and over , Periprosthetic Fractures/surgery , Arthroplasty, Replacement, Shoulder , Humeral Fractures/surgery , Bone Plates , Treatment Outcome , Periprosthetic Fractures/diagnostic imaging , Humeral Fractures/diagnostic imaging
5.
Rev. bras. ortop ; 52(4): 396-401, July-Aug. 2017. graf
Article in English | LILACS | ID: biblio-1042406

ABSTRACT

ABSTRACT To evaluate the mechanical stress and elastic deformation exercised in the thread/shaft transition of Schanz screws in assemblies with different screw anchorage distances in the entrance to the bone cortex, through the distribution and location of tension in the samples. An analysis of 3D finite elements was performed to evaluate the distribution of the equivalent stress (triple stress state) in a Schanz screw fixed bicortically and orthogonally to a tubular bone, using two mounting patterns: (1) thread/shaft transition located 20 mm from the anchorage of the Schanz screws in the entrance to the bone cortex and (2) thread/shaft transition located 3 mm from the anchorage of the Schanz screws in entrance to the bone cortex. The simulations were performed maintaining the same direction of loading and the same distance from the force vector in relation to the center of the hypothetical bone. The load applied, its direction, and the distance to the center of the bone were constant during the simulations in order to maintain the moment of flexion equally constant. The present calculations demonstrated linear behavior during the experiment. It was found that the model with a distance of 20 mm between the Schanz screws anchorage in the entrance to the bone cortex and the thread/shaft transition reduces the risk of breakage or fatigue of the material during the application of constant static loads; in this model, the maximum forces observed were higher (350 MPa). The distance between the Schanz screws anchorage at the entrance to the bone cortex and the smooth thread/shaft transition of the screws used in a femoral distractor during acute distraction of a fracture must be farther from the entrance to the bone cortex, allowing greater degree of elastic deformation of the material, lower mechanical stress in the thread/shaft transition, and minimized breakage or fatigue. The suggested distance is 20 mm.


RESUMO Avaliar o comportamento do estresse mecânico e da deformação elástica exercida na transição rosca-talo liso dos pinos de Schanz do distrator femoral de fraturas em montagens com diferentes distâncias de ancoragem dos pinos na cortical óssea de entrada através de estudo da distribuição e da localização de tensões no corpo de prova. Feita análise de elementos finitos 3 D para a avaliação da distribuição das tensões equivalentes em um pino de Schanz fixado de modo bicortical e ortogonal a um osso tubular, em dois padrões de montagem: (1) transição rosca-talo liso distante 20 mm da ancoragem dos pinos de Schanz na cortical de entrada e (2) transição rosca-talo liso distante 3 mm da ancoragem dos pinos de Schanz na cortical de entrada. Foram feitas simulações e manteve-se a mesma direção da carga e a mesma distância do vetor força em relação ao centro do osso hipotético. A carga aplicada, sua direção e a distância ao centro do osso foram constantes durante as simulações para manter o momento fletor igualmente constante. Os cálculos apresentados demonstraram comportamento linear durante todo o experimento. Verificou-se que o modelo com uma distância de 20 mm entre a ancoragem dos pinos de Schanz na cortical óssea de entrada e a transição rosca-talo liso reduziu o risco de ruptura ou fadiga do material durante a aplicação de cargas estáticas constantes. Nesse modelo, as forças máximas observadas foram superiores (350 Mpa). A análise do comportamento do estresse mecânico e da deformação elástica exercida na transição rosca-talo liso dos pinos de Schanz do distrator femoral de fraturas mostrou que distâncias maiores entre a ancoragem dos pinos na cortical óssea de entrada e a transição rosca-talo liso dos pinos de Schanz permitem menor estresse mecânico na transição rosca-talo liso e maior grau de deformação elástica do material e minimizam quebra ou fadiga. A distância sugerida é de 20 mm.


Subject(s)
Bone Nails , External Fixators , Treatment Outcome , Finite Element Analysis , Femoral Fractures
6.
Rev. Col. Bras. Cir ; 44(4): 328-339, jul.-ago. 2017. tab, graf
Article in Portuguese | LILACS | ID: biblio-896601

ABSTRACT

RESUMO Objetivo: avaliar a conduta de cirurgiões ortopédicos da América Latina na definição da área de trabalho em distintos padrões de fratura da diáfise do fêmur. Métodos: foi desenvolvido um questionário em que foram apresentadas opções de fixação extra-medular em quatro padrões de fratura da diáfise do fêmur com três diferentes áreas de trabalho. O questionário foi submetido aos participantes utilizando-se a ferramenta Googleforms. A associação entre as características profissionais e as opções de conduta médica de acordo com cada tipo de fratura foi analisada pelo teste de qui-quadrado, com nível de significância de 5%. Resultados: setecentos e sete profissionais da América Latina responderam o questionário. A maioria dos participantes optou por uma menor área de trabalho na osteossíntese em todas as situações do estudo. Observou-se associação significativa entre a especialidade e a conduta médica nas fraturas do tipo AO 32-B3 e 32-C2 (p < 0,05). As demais características profissionais não mostraram associação significativa. Conclusão: a maioria dos participantes deste estudo prefere construções com menor área de trabalho, representando aproximadamente um terço do comprimento total da placa, independentemente do padrão de fratura. Houve associação significativa entre o tipo de especialidade (trauma ortopédico) e as opções de conduta para as fraturas do tipo AO 32-B3 e 32-C. O presente estudo reforça a importância da compreensão do conceito de área de trabalho, mostrando que sua estimativa continua sendo baseada mais na experiência do cirurgião do que em conceitos biomecânicos que regem o processo de consolidação de fraturas.


ABSTRACT Objective: to evaluate how orthopedic surgeons in Latin America define the working length for distinct patterns of femoral shaft fracture. Methods: a survey was developed presenting different options of working length in four femoral fracture patterns. The survey was submitted to the participants using Google Forms tool. The association between professional characteristics and medical management options according to each type of fracture was analyzed by Chi-square test, with 5% significance level. Results: seven hundred and seven professionals from all Latin America answered the survey. The majority prefered a smaller working length for all situations presented in the study. There was a significant association between the main interest area and the medical preference for the management in fracture types AO 32-B3 and 32-C2 (p<0.05). Other professional characteristics had no significant association at the level of 5%. Conclusion: most of the study participants preferred constructions with smaller working length, representing approximately one-third of the total length of the plate, regardless of fracture pattern. There was a significant association between the main interest area (orthopedic trauma) and medical management options for fracture type AO 32-B3 and 32-C2. This can be attributed in part to the fact that these two types of fractures are considered, in the view of the authors, intermediate patterns in terms of strain. This study reinforces the importance of understanding the concept of working length, showing that its calculation remains more based on the surgeons' experience than grounded by strong biomechanical concepts governing the fracture healing process.


Subject(s)
Humans , Orthopedics , Bone Plates , Practice Patterns, Physicians' , Femoral Fractures/surgery , Fracture Fixation, Intramedullary/instrumentation , Cross-Sectional Studies , Health Care Surveys , Internet , Internationality , Equipment Design
7.
Rev. bras. ortop ; 52(4): 410-416, July-Aug. 2017. tab, graf
Article in English | LILACS | ID: biblio-899159

ABSTRACT

ABSTRACT OBJECTIVE: To evaluate the decision of orthopedics surgeons regarding which cases they would indicate surgery or non-surgical treatment. METHODS: 20 images of radiographs with fracture in the middle third of the collar bone (AO/OTA 15-B) in anteroposterior view were analyzed, and divided into four groups: group 1 - fracture type AO/OTA 15-B1 without displacement; group 2 - fracture type AO/OTA 15-B1 with displacement; group 3 - fracture type AO/OTA 15-B2; group 4 - fracture type AO/OTA 15-B3. The evaluator was requested to indicate the choice of treatment, surgical or non-surgical. RESULTS: There was no strong correlation between the amount of surgical indications and the working experience or age of the medical evaluator. It was observed that the average of surgical indications in the total sample was 52%. When indications were studied in different areas of Brazil, there was no significant difference among them. No pattern for the Brazilian regions studied was observed in the case analysis. Even within a group (cases of the same complexity), no specific pattern of surgical indication was observed. CONCLUSION: No association between surgical indication and the length of professional experience was found. The Southern and Southeastern regions were those that most recommended surgeries in groups 2, 3, and 4. In no region the same level of surgical indication for cases of the same complexity rate was kept.


RESUMO OBJETIVO: Avaliar a decisão de cirurgiões ortopédicos sobre em que casos indicariam a cirurgia ou tratariam não cirurgicamente. MÉTODOS: Foram analisadas 20 imagens de radiografias com fratura do terço médio da clavícula (AO/OTA 15-B) em incidência anteroposterior, que foram divididas em quatro grupos: 1 - fratura do tipo AO/OTA 15-B1 sem desvio; 2 - fratura do tipo AO/OTA 15-B1 com desvio; 3 - fratura do tipo AO/OTA 15-B2; 4 - fratura do tipo AO/OTA 15-B3. Ao avaliador, foi solicitado que indicasse o tipo de tratamento: cirúrgico ou não cirúrgico. RESULTADOS: Não houve correlação forte entre a quantidade de indicações cirúrgicas e o tempo de atuação do médico avaliador ou sua idade. Verificou-se que a média de indicação de cirurgias no total da amostra foi de 52%. Quando estudadas as indicações por diferentes regiões do Brasil, não houve diferença significativa. Não foi verificado qualquer padrão para as regiões brasileiras na análise por caso. Mesmo dentro de um grupo (casos de mesma complexidade), não foi verificado um padrão específico de indicação cirúrgica. CONCLUSÃO: Não foi verificada associação entre a indicação cirúrgica e o tempo de atuação do profissional. As regiões Sul e Sudeste são as que mais recomendam a cirurgia dos grupos 2, 3 e 4. Verificou-se que em nenhuma região foi mantido o mesmo nível de indicação de cirurgias para casos do mesmo grau de complexidade.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Bone Plates , Clavicle/diagnostic imaging , Clavicle/surgery , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery
8.
Acta ortop. bras ; 25(1): 48-51, Jan.-Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-837740

ABSTRACT

ABSTRACT Objective: To evaluate the frequency of deltoid ligament injury in bimalleolar supination-external rotation type fractures and whether there is a correlation between the size of the fractured medial malleolus and deltoid ligament injury . Methods: Twenty six consecutive patients underwent magnetic resonance exams after clinical and radiographic diagnosis of bimalleolar supination-external rotation type ankle fractures . Results: Thirteen patients (50%) presented deltoid ligament injury associated to bimalleolar ankle fracture. Partial injury was present in seven (26.9%) patients and total injury in six (23.1%). Regarding medial fragment size, the average was 2.88 cm in the absence of deltoid ligament injury. Partial injuries presented 1.93 cm and total 2.1 cm on average . Conclusion: Deltoid ligament injury was present in 50% of bimalleolar ankle fractures. Smaller medial malleolus fragments, especially concerning the anterior colliculus, presented greater association with partial deltoid ligament injuries. Level of Evidence IV, Cross Sectional Study.


RESUMO Objetivo: Avaliar a frequência da lesão do ligamento deltóide nas fraturas bimaleolares do tornozelo tipo supinação-rotação externa e se existe correlação entre o tamanho do fragmento do maléolo medial fraturado e o tipo de lesão do ligamento deltóide. Métodos: Vinte e seis pacientes consecutivos com diagnóstico clínico e radiográfico de fratura bimaleolar do tornozelo tipo supinação-rotação externa (Lauge-Hansen), foram submetidos ao exame de ressonância magnética do tornozelo para avaliar a presença de lesão ligamentar associada à fratura bimaleolar. Resultados: Treze pacientes (50%) apresentaram lesão do ligamento deltóide associada à fratura bimaleolar do tornozelo, sendo sete (26,9%) lesões parciais e seis (23,1%) totais. Com relação ao tamanho do fragmento do maléolo medial, na ausência de lesão do ligamento deltóide, o tamanho médio foi de 2,88 cm. Nas lesões parciais, a média foi de 1,93 cm e, nas lesões totais do ligamento deltóide, de 2,1 cm. Conclusões: A lesão do ligamento deltóide esteve presente em metade das fraturas bimaleolares do tornozelo do tipo supinação-rotação externa. Fragmentos menores do maléolo medial, especialmente do colículo anterior, tem maior associação com lesões parciais do ligamento deltóide. Nível de Evidência IV, Estudo Transversal.

9.
Rev. bras. ortop ; 51(6): 735-738, Nov.-Dec. 2016. graf
Article in English | LILACS | ID: biblio-830027

ABSTRACT

ABSTRACT Bilateral stress fracture of femoral neck in healthy young patients is an extremely rare entity, whose diagnostic and treatment represent a major challenge. Patients with history of hip pain, even non-athletes or military recruits, should be analyzed to achieve an early diagnosis and prevent possible complications from the surgical treatment. This report describes a 43-year-old male patient, non-athlete, without previous diseases, who developed bilateral stress fracture of femoral neck without displacement. He had a late diagnosis; bilateral osteosynthesis was made using cannulated screws. Although the diagnosis was delayed in this case, the study highlights the importance of the diagnosis of stress fracture, regardless of the activity level of the patients, for the success of the treatment.


RESUMO A fratura de estresse bilateral do colo do fêmur em pacientes adultos sadios é uma entidade extremamente rara, cujo diagnóstico e tratamento representam um grande desafio. Pacientes com história de dor no quadril, mesmo se não forem atletas ou militares, devem ser analisados para se obter um diagnóstico precoce e prevenir possíveis complicações provenientes do tratamento cirúrgico. Este relato descreve um paciente de 43 anos, não atleta, do gênero masculino, sem doenças prévias, que desenvolveu fratura de estresse do colo do fêmur bilateral sem desvio, diagnosticado e tratado tardiamente com osteossíntese bilateral com parafusos canulados. Apesar de o diagnóstico ter sido tardio nesse caso, enfatiza-se a importância de se obter diagnóstico de fratura de estresse, independentemente do nível de atividade dos pacientes, para o sucesso do tratamento.


Subject(s)
Humans , Male , Middle Aged , Femoral Fractures , Fractures, Bone , Fractures, Stress , Hip , Pain
10.
Rev. bras. ortop ; 51(5): 601-605, Sept.-Oct. 2016. graf
Article in English | LILACS | ID: biblio-830001

ABSTRACT

ABSTRACT The authors report the cases of two young patients who had suffered a sporting accident with posterior traumatic dislocation of sternoclavicular joint. In one of the patients closed reduction was accomplished by keeping the limb in a sling. The second patient, after reduction was done, presented recurrence of the dislocation, thus requiring surgical treatment. It is important to observe the relevance of computed tomography to help diagnosing, as well as monitoring the reduction procedure. The objective of this study was to demonstrate two different types of treatment in a rare injury such as the posterior dislocation of sternoclavicular joint.


RESUMO Relato de caso de dois jovens que se acidentaram no esporte e apresentaram luxação traumática posterior da articulação esternoclavicular. Em um paciente foi feita a redução incruenta e manutenção com tipoia. O segundo paciente, após a redução, apresentou recidiva da luxação, foi necessário o tratamento cirúrgico. Vale salientar a importância da tomografia computadorizada no auxílio do diagnóstico, assim como para monitorar a redução. O objetivo deste estudo foi demonstrar dois tipos diferentes de tratamento em uma lesão rara como a luxação traumática posterior da articulação esternoclavicular.


Subject(s)
Humans , Male , Adolescent , Sternoclavicular Joint/injuries , Surgical Procedures, Operative
11.
Rev. bras. ortop ; 51(2): 208-213, Mar.-Apr. 2016. tab, graf
Article in English | LILACS | ID: lil-779991

ABSTRACT

OBJECTIVE: To ascertain whether the number of screws or pins placed in the calcaneus might increase the risk of injury when three different techniques for treating calcaneal fractures. METHOD: 126 radiographs of patients who suffered displaced calcaneal fractures were retrospectively analyzed. Three surgical techniques were analyzed on an interobserver basis: 31 radiographs of patients treated using plates that were not specific for the calcaneus, 48 using specific plates and 47 using an external fixator. The risk of injury to the anatomical structures in relation to each Kirschner wire or screw was determined using a graded system in accordance with the Licht classification. The total risk of injury to the anatomical structures through placement of more than one wire/screw was quantified using the additive law of probabilities for the product, for independent events. RESULTS: All of the models presented high explanatory power for the risk evaluated, since the coefficient of determination values (R2) were greater than 98.6 for all the models. Therefore, the set of variables studied explained more than 98.6% of the variations in the risks of injury to arteries, veins or nerves and can be classified as excellent models for prevention of injuries. CONCLUSION: The risk of injury to arteries, veins or nerves is not defined by the total number of pins/screws. The region and the number of pins/screws in each region define and determine the best distribution of the risk.


OBJETIVO: Verificar se o número de parafusos ou pinos colocados no calcanhar aumentaria o risco de lesão quando usamos três técnicas diferentes para o tratamento das fraturas. MÉTODO: Foram analisadas retrospectivamente 126 radiografias de pacientes que sofreram fratura desviada do calcanhar. Foram analisadas três técnicas cirúrgicas sob a forma interobservador: 31 radiografias de pacientes tratados com placa não específica para o calcanhar, 48 com placa específica e 47 com fixador externo. O risco de lesão das estruturas anatômicas em relação a cada fio de Kirschner ou parafuso foi determinado pelo sistema de graduação segundo a classificação de Licht. A quantificação do risco total de lesão das estruturas anatômicas na colocação de mais de um fio/parafuso foi calculada pela lei aditiva das probabilidades do produto para eventos independentes. RESULTADOS: Todos os modelos apresentaram um alto poder de explicação do risco avaliado, uma vez que os valores do coeficiente de determinação R2 são maiores do que 98,6 para todos os modelos. Portanto, o conjunto de variáveis estudado explica mais de 98,6% das variações dos riscos de lesão das artérias, veias ou dos nervos e podem ser classificados como excelentes modelos para prevenção de lesões. CONCLUSÃO: O risco de lesão das artérias, veias ou dos nervos não é definido pelo total de pinos/parafusos. A região e a quantidade de pinos/parafusos em cada região definem e determinam melhor a distribuição do risco.


Subject(s)
Humans , Male , Female , Bone Nails , Bone Screws , Calcaneus/injuries , Surgical Procedures, Operative
12.
Rev. bras. ortop ; 51(1): 24-28, Jan.-Feb. 2016. tab, graf
Article in Portuguese | LILACS | ID: lil-775655

ABSTRACT

To analyze fractures of the distal clavicle region in pediatric patients. METHODS: Ten patients between the ages of five to eleven years (mean of 7.3 years) were observed. Nine patients were treated conservatively and one surgically. All the fractures were classified using the Nenopoulos classification system. RESULTS: All the fractures consolidated without complications. Conservative treatment was used for nine patients, of whom three were in group IIIB, three IIb, two IIa and one IV. The only patient who was treated surgically was a female patient of eleven years of age with a group IV fracture. CONCLUSION: The treatment indication for distal fractures of the clavicle in children should be based on the patient's age and the displacement of the fragments.


Analisar as fraturas da região distal da clavícula em pacientes pediátricos. MÉTODOS: Foram observados dez pacientes entre cinco a 11 anos com média de 7,3 anos. Nove pacientes foram tratados conservadoramente e um cirurgicamente. As fraturas foram classificadas segundo a classificação de Nenopoulos. RESULTADOS: Todas as fraturas consolidaram sem complicações. O tratamento conservador foi usado em nove pacientes, três do grupo IIIb; três IIb; dois IIa e um IV. O único paciente tratado cirurgicamente foi uma paciente do gênero feminino de 11 anos com fratura do grupo IV. CONCLUSÃO: A indicação do tratamento para as fraturas distais da clavícula em crianças deve ser baseada na idade do paciente e no desvio dos fragmentos.


Subject(s)
Humans , Male , Female , Child , Clavicle , Fractures, Bone
13.
Coluna/Columna ; 14(3): 210-213, July-Sept. 2015. tab, graf
Article in English | LILACS | ID: lil-762972

ABSTRACT

Objective: To evaluate the bone area of the odontoid process through computed tomography and its relation with the area of one and two screws in the male and female subjects. Methods: 188 CT scans of adults were analyzed. The isthmus area was selected and the transverse diameter was measured at 1.2 mm from the base of odontoid. Results: After placement of a screw, the odontoid area remains with 82% of free bone for both men and women. With two screws, 45.6% of women, had a free bone area of the odontoid process between 50% and 75% and 54.4% were above 75%. 26.6% men had percentage from 50% to 75% of free bone area and 73.4% above 75% (p=0.07). After the placement of two screws, the bone area was, in average, 77.3% in men and 75.4% in women. Using the Student t-test, the differences between the average of percentage of free bone area in men and women are significantly lower in women (p=0.0012). Conclusion: The pre-operative planning through CT can help to choose the number of screws in the odontoid process. The choice should be particularly careful when using two screws in women.


Objetivo: Avaliar a área óssea do processo odontoide, por meio de tomografia computadorizada e sua relação com a área de um e dois parafusos em indivíduos do sexo masculino e feminino. Métodos: Foram analisadas 188 tomografias computadorizadas de adultos. A área do istmo foi selecionada e o diâmetro transverso foi medido a 1,2 mm da base do odontoide. Resultados: Após a colocação de um parafuso, a área do odontoide permanece com 82% de osso livre, tanto para homens quanto para mulheres. Com dois parafusos, 45,6% das mulheres, passaram a ter área óssea livre do processo odontoide entre 50% e 75%, e 54,4% ficaram acima de 75%. Entre os homens este percentual foi de 26,6% entre 50% a 75% de área óssea livre e 73,4% acima de 75% (valor de p = 0,07). Após a colocação de dois parafusos, a área óssea foi, em média, 77,3% nos homens e 75,4% nas mulheres. Utilizando o teste t de Student, as diferenças entre as médias de homens e mulheres dos percentuais da área óssea livre são significativamente menores nas mulheres (valor de p = 0,0012). Conclusão: O planejamento no pré-operatório, por meio de TC, pode ajudar na escolha do número de parafusos no processo odontoide. A escolha deve ser criteriosa, especialmente quando for necessária a utilização de dois parafusos no gênero feminino.


Objetivo: Evaluar el área ósea del proceso odontoides por medio de la tomografía axial computarizada, y su relación con el área de uno y dos tornillos en individuos del sexo masculino y femenino. Métodos: Fueron analizadas 188 tomografías axiales computarizadas de adultos. Se seleccionó el área del istmo y el diámetro transversal fue medido en 1,2 mm de la base del odontoides. Resultados: Después de la colocación de un tornillo, el área de la odontoides queda con 82% de hueso libre, tanto en hombres como en mujeres. Con dos tornillos, el 45,6% de las mujeres tuvieron área de hueso libre en el proceso odontoides entre el 50% y el 75%, y 54,4% estaban por encima del 75%. Entre los hombres este porcentaje fue del 26,6% desde el 50% al 75% de área de hueso libre y el 73,4% por encima del 75%, (p = 0,07). Después de la colocación de dos tornillos, el área de hueso fue, en promedio, el 77,3% de los hombres y el 75,4% de las mujeres. Utilizando la prueba t de Student, las diferencias entre las medias de hombres y mujeres del porcentaje de área de hueso libre son significativamente más bajos en las mujeres (p = 0,0012). Conclusión: La planificación prequirúrgica mediante TC puede ayudar a elegir el número de tornillos a usar en el proceso odontoides. La elección debe ser cuidadosa, especialmente cuando se utilizan dos tornillos en las mujeres.


Subject(s)
Humans , Odontoid Process/diagnostic imaging , Bone Screws , Preoperative Care/instrumentation , Tomography, X-Ray Computed
14.
Rev. bras. ortop ; 50(1): 30-37, Jan-Feb/2015. tab, graf
Article in English | LILACS | ID: lil-744644

ABSTRACT

To analyze the tip-apex distance (TAD), cervicodiaphyseal angle and Garden angle in stable and unstable extracapsular fractures of the femur treated with a plate and sliding screw. METHOD: Hip radiographs in anteroposterior (AP) and lateral view on 117 patients were evaluated. The fractures were classified as stable or unstable, using the AO classification, and the reduction achieved was assessed in accordance with the following criteria: TAD > 3 cm; Garden alignment index (AP) < 160°; and AP cervicodiaphyseal varus angle < 125°. When two or more criteria were present, the quality of the osteosynthesis was classified as "not ideal". RESULTS: The patients with unstable fractures presented AP cervicodiaphyseal angles that were significantly greater (p = 0.05) than in those with stable fractures. The patients with unstable fractures presented lateral cervicodiaphyseal angles that were significantly smaller (p = 0.05) than in those with stable fractures. There were no significant differences in the remainder of the criteria evaluated. CONCLUSION: This study did not find any significant differences in the measurements evaluated, except in relation to the cervicodiaphyseal angle. Satisfactory reduction was achieved both for the stable and for the unstable fractures, when we used a plate and sliding screw to treat proximal extracapsular fractures of the femur...


Analisar a distância ponta-ápice (DPA), o ângulo cervicodiafisário e o ângulo de Garden em fraturas extracapsulares instáveis e estáveis do fêmur tratadas com placa e parafuso deslizante. MÉTODO: Foram avaliadas radiografias do quadril nas incidências em anteroposterior (AP) e perfil de 117 pacientes. As fraturas foram classificadas como estáveis e instáveis, pela classificação AO, e a redução obtida foi avaliada de acordo com os critérios de distância ponta-ápice (DPA > 3 cm), índice de alinhamento de Garden (AP) < 160° e ângulo cervicodiafisário (AP) em varo < 125°. Quando dois ou mais critérios estavam presentes, a qualidade da osteossíntese foi classificada como "não ideal". RESULTADOS: Os pacientes com fratura instável apresentaram CD AP (p = 0,05) significativamente maior do que os estáveis. Os pacientes com fratura instável apresentaram o CD Perfil (p = 0,05) significativamente menor do que os com fratura estável. Não houve diferença significativa entre o restante dos critérios avaliados. CONCLUSÃO: Este estudo não encontrou diferença significativa entre as medidas avaliadas, exceto o ângulo cervicodiafisário. Foi conseguida uma redução satisfatória, tanto nas fraturas estáveis como nas instáveis, quando usamos placa e parafuso deslizante nas fraturas proximais extracapsulares do fêmur...


Analisar a distância ponta-ápice (DPA), o ângulo cervicodiafisário e o ângulo de Garden em fraturas extracapsulares instáveis e estáveis do fêmur tratadas com placa e parafuso deslizante. MÉTODO: Foram avaliadas radiografias do quadril nas incidências em anteroposterior (AP) e perfil de 117 pacientes. As fraturas foram classificadas como estáveis e instáveis, pela classificação AO, e a redução obtida foi avaliada de acordo com os critérios de distância ponta-ápice (DPA > 3 cm), índice de alinhamento de Garden (AP) < 160° e ângulo cervicodiafisário (AP) em varo < 125°. Quando dois ou mais critérios estavam presentes, a qualidade da osteossíntese foi classificada como "não ideal". RESULTADOS: Os pacientes com fratura instável apresentaram CD AP (p = 0,05) significativamente maior do que os estáveis. Os pacientes com fratura instável apresentaram o CD Perfil (p = 0,05) significativamente menor do que os com fratura estável. Não houve diferença significativa entre o restante dos critérios avaliados. CONCLUSÃO: Este estudo não encontrou diferença significativa entre as medidas avaliadas, exceto o ângulo cervicodiafisário. Foi conseguida uma redução satisfatória, tanto nas fraturas estáveis como nas instáveis, quando usamos placa e parafuso deslizante nas fraturas proximais extracapsulares do fêmur...


Subject(s)
Humans , Male , Female , Bone Screws , Femoral Fractures , Hip Fractures
15.
Rev. bras. ortop ; 49(1): 78-81, Jan-Feb/2014. graf
Article in Portuguese | LILACS | ID: lil-707176

ABSTRACT

A fasciíte necrosante é uma rara e potencialmente letal infecção de partes moles. A seguir, descreveremos o caso de uma paciente portadora de fratura transtrocantérica do fêmur que evoluiu com fasciíte necrosante após a osteossíntese da fratura. Uma revisão da literatura acerca do tema será abordada.


Necrotizing fasciitis is a rare and potentially lethal soft tissue infection. We report a case of trochanteric femur fracture in a patient who underwent fracture fixation and developed necrotizing fasciitis. A literature review on the topic will be addressed.


Subject(s)
Humans , Female , Aged , Fasciitis, Necrotizing , Femoral Fractures , Fracture Fixation, Internal , Hip Fractures , Surgical Wound Infection
16.
Rev. bras. ortop ; 48(3): 228-235, May/June/2013. tab, graf
Article in English | LILACS | ID: lil-680876

ABSTRACT

OBJECTIVE: Compare the level of vitamin D with the bone mineral density (BMD) in postmenopausal women, with or without fractures. METHODS: 250 women with mean age of 71.1 were evaluated. The serum levels of vitamin D considered sufficient were ≥ 30 ng/mL, insufficient between 20 and 30 ng/mL and deficient < 20 ng/mL. The bone mineral density was measured and considered osteopenia when T value total of lumbar spine or hip was between -1 and -2.5 and osteoporosis < 2.5. The patients with fractures accounted for 25.2%. RESULTS: There was no significant difference in the vitamin D (ng/mL) levels among the age groups (p = 0.25), the levels of fractures (p = 0.79) and the levels of BMD (p = 0.76). CONCLUSION: 82% of the patients presented deficient and insufficient blood levels of vitamin D. Ours results showed any significant correlation between vitamin D levels and bone mineral density after adjusting for age. .


OBJETIVO: Comparar o nível de vitamina D com a densidade mineral óssea (DMO) em mulheres na pós-menopausa, com ou sem fraturas. MÉTODOS : Foram avaliadas 250 mulheres com idade média de 71,1 anos. Os níveis séricos de vitamina D foram considerados normais quando ≥ 30 ng/mL, insuficientes entre 20 e 30 ng/mL e deficientes < 20 ng/mL. A DMO foi medida e considerada osteopenia quando o valor total T da coluna lombar ou do quadril estava entre -1 e -2,5 e osteoporose quando < -2,5. As pacientes com fratura somavam 25,2%. RESULTADOS : Não existiu diferença significativa na dosagem de vitamina D (ng/mL) entre as faixas etárias (p = 0,25), os níveis de fratura (p = 0,79) e os níveis da DMO (p = 0,76). CONCLUSÃO : Das pacientes, 82% apresentaram níveis séricos de vitamina D deficientes e insuficientes. Nossos resultados não demonstraram correlação significativa entre os níveis de vitamina D e DMO com a idade.. .


Subject(s)
Humans , Female , Middle Aged , Aged, 80 and over , Bone Density , Fractures, Bone , Osteoporosis, Postmenopausal , Vitamin D
17.
Acta ortop. bras ; 20(2): 79-83, 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-622367

ABSTRACT

OBJETIVO: Avaliar se existe correlação entre parâmetros radiográficos da anatomia da região proximal do fêmur e a ocorrência de fraturas. MÉTODOS: Trezentas e cinco radiografias digitais da bacia foram analisadas na incidência ântero-posterior. Destas radiografias, vinte e sete apresentavam fratura do colo femoral ou transtrocantérica. Os parâmetros anatômicos analisados foram: Largura do colo femoral (LCF), comprimento do colo femoral (CCF), comprimento do eixo femoral (CEF), ângulo cérvico-diafisário (ACD), distância entre as lágrimas acetabulares (DLA) e a distância grande trocânter- sínfise púbica (DGTSP).Foram analisadas, comparativamente, as radiografias com e sem fratura da região proximal do fêmur, para verificar se existem parâmetros radiográficos que estão associados com maior probabilidade de ocorrência de fratura do colo femoral ou transtrocantérica. RESULTADOS: Não foi encontrada diferença entre os parâmetros anatômicos dos grupos com e sem fratura na região proximal do fêmur. CONCLUSÃO: Não foi encontrada nenhuma associação entre alterações anatômicas na região proximal do fêmur e maior susceptibilidade à ocorrência de fraturas. Nível de evidência IV, Estudo Transversal.


OBJECTIVE: To evaluate the correlation between radiographic parameters of the proximal femur anatomy and fractures. METHODS: Three hundred and five digital x-rays of the pelvis were analyzed in the anteroposterior view. Of these x-rays, twenty-seven showed femoral neck or transtrochanteric fractures. The anatomical parameters analyzed were: femoral neck width (FNW), femoral neck length (FNL), femoral axis length (FAL), cervicodiaphyseal angle (CDA), acetabular tear-drop distance (ATD) and great trochanter-pubic symphysis distance (GTPSD). The analysis was performed by comparing the results of the x-rays with and without proximal femoral fracture, to establish a correlation between them. RESULTS: No differences were found between the anatomical parameters of the groups with and without proximal femoral fracture. CONCLUSION: There was no association between anatomical changes in the proximal femur and greater susceptibility to fractures. Level of evidence IV, Cross-sectional Study.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged, 80 and over , Femoral Fractures , Hip Fractures/complications , Hip Fractures/prevention & control , Radiography , Risk Factors
18.
Rev. méd. Minas Gerais ; 21(2)abr.-jun. 2011. tab, graf
Article in Portuguese | LILACS | ID: lil-598702

ABSTRACT

Para que o tratamento de uma fratura de extremidade seja instituído, é fundamental que se faça minucioso exame físico, complementado pela radiografia. No entanto, não raramente, a análise radiográfica é feita confrontando-se o filme com a luz da janela ou da sala de emergência, e não com o negatoscópio. O presente estudo tem como objetivo observar se as condições da visibilização realmente influenciam na análise radiográfica de pacientes vítimas de trauma de extremidade.


Before prescribing a treatment, physicians are supposed to carry on detailed physical exams complemented with radiography analysis. However, they frequently analyze radiographies against the light shining from the window or in the emergency room, instead of using a negatoscope. This study aims at investigating whether visualization conditions do have an impact on the analysis of radiographies of extremity fracture patients.


Subject(s)
Humans , Extremities , Radiography/instrumentation , Extremities/injuries , Lighting
19.
Acta ortop. bras ; 18(4): 197-199, 2010. tab
Article in English, Portuguese | LILACS | ID: lil-554646

ABSTRACT

OBJETIVO: Avaliar a reprodutibilidade interobservadores das classificações AO/ASIF e de Winquist para as fraturas diafisárias do fêmur no adulto. MÉTODOS: foram selecionadas aleatoriamente 50 radiografias de pacientes adultos portadores de fratura diafisária do fêmur nas incidências em antero-posterior e perfil. As radiografias foram analisadas por 5 observadores, sendo um membro da Sociedade Brasileira de Trauma Ortopédico, um radiologista, um residente do terceiro ano de Ortopedia e Traumatologia, um do segundo e um do primeiro. Para avaliar a concordância interobservadores destas classificações, foi utilizado o índice estatístico Kappa (K). RESULTADOS: Em todas as análises, observou-se um coeficiente de concordância entre observadores estatisticamente significativo (valor p < 0,05) e classificado como bom (valores de 0,61 a 0,80) ou muito bom (valores acima de 0,80), segundo os critérios de Landis e Koch. CONCLUSÃO: As classificações AO e Winquist apresentam alto índice de concordância interobservadores para as fraturas diafisárias do fêmur no adulto.


OBJECTIVE: To evaluate inter-observer reproducibility of AO / ASIF and Winquist-Hansen classifications for shaft fractures of the femur in adults. METHODS: 50 anterior-posterior and profilelateral radiographs were randomly selected, of adult patients awith diaphyseal fracture of the femur. The radiographs were analyzed by 5 observers-a member of the Brazilian Society of Orthopedic Trauma, a radiologist and 3 residents. To assess the concordance between these classifications, we used the statistical index Kappa (K). RESULTS: In all analyses, we observed a statistically significant correlation coefficient between observers (p <0.05) and according to the criteria of Landis and Koch, they were ranked them as good (values of 0.61 to 0.80) or very good (values above 0.80). CONCLUSION: The AO rating and Winquist present a high rate of concordance between observers for shaft fractures of the femur in adults.


Subject(s)
Humans , Adult , Femoral Fractures , Femoral Fractures , Image Interpretation, Computer-Assisted , Classification , Diagnostic Imaging , Reproducibility of Results
20.
Acta ortop. bras ; 18(4): 200-203, 2010. ilus, graf
Article in English, Portuguese | LILACS | ID: lil-554647

ABSTRACT

OBJETIVO: Verificar se a biópsia da sinóvia do túnel do carpo é capaz de identificar patologias sistêmicas que não foram diagnosticadas clinicamente ou por exames laboratoriais. MÉTODO: 46 exames anatomopatológicos da sinóvia dos tendões flexores no túnel do carpo de pacientes submetidos à liberação aberta para o tratamento desta síndrome compressiva foram, retrospectivamente, analisados. Os autores propuseram uma nova classificação para a lesão de acordo com a intensidade do processo inflamatório. RESULTADOS: O exame anatomopatológico mostrou que 56,6 por cento das lâminas foram classificadas como grau I (sem alterações inflamatórias), 32,6 por cento, grau II (infiltrado leucocitário e fibrose discretos, além de hialinose), 4,3 por cento, grau III (infiltrado leucocitário e fibrose intensos, presença de fibrina e neoformação vascular) e 6,5 por cento, grau IV (as alterações acima descritas associadas à presença de calcificação local e células gigantes). Dois pacientes com amiloidose foram classificados como graus I e II e não foram encontrados depósitos de material amilóide em suas lâminas. Dois pacientes portadores de hiperparatireoidismo e outro com insuficiência renal crônica foram classificados como grau IV. CONCLUSÃO: A realização da biópsia da sinóvia do túnel do carpo, além de agregar custos adicionais ao procedimento, não possibilitou o diagnóstico precoce de doenças sistêmicas em pacientes portadores de síndrome do túnel do carpo.


OBJECTIVE: To determine whether a biopsy of the synovia of the carpal tunnel is able to identify systemic diseases that were not diagnosed by clinical examination and laboratory tests. METHODS: Anatomical pathology P examinations of synovial tissue were performed in 46 patients that underwent open carpal tunnel release. Anatomical pathology examination with hematoxylin-eosin staining determined the intensity of the inflammatory process and the authors proposed a new classification of the injury according to the intensity of the inflammatory process. RESULTS: The anatomical pathology examination showed that 56.6 percent were classified as grade I (unchanged inflammation), 32.6 percent, grade II (leukocyte infiltration and discreetmoderate fibrosis), 4.3 percent, grade III (leukocyte infiltrate and intense fibrosis, the presence of fibrin and vascular neoformation) and 6.5 percent, grade IV (changes described above associated with the presence of local calcification and giant cells). Two patients with amyloidosis were classified as grade I and II and no stockpiles of amyloid material were found on their slides. Two patients with hyperparathyroidism and another with chronic kidney failure were classified as grade IV. CONCLUSION: Synovial biopsy of the carpal tunnel did not make early diagnosis of potential systemic diseases possiblein patients with carpal tunnel syndrome, and adds extra costs to the procedure.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged, 80 and over , Wrist/anatomy & histology , Synovial Fluid , Carpal Tunnel Syndrome/pathology , Carpal Tunnel Syndrome/rehabilitation , Biopsy , Nerve Crush